Upon earning a degree in Zoology at North Carolina State University, Joy made her debut in the pharmaceutical industry in 1992 at Pharmacia & UpJohn performing Environmental Monitoring and Sterility Testing. Her hard work allowed her to move into a supervisory role at Abbott Laboratories where she oversaw their Quality Control Lab. In 1998 Joy moved to Wyeth Lederle and worked in Quality Assurance, performing GMP Compliance audits, batch record reviews, and holding annual GMP training for new employees. After working in Quality Assurance for a few years, Joy moved into Equipment Qualification and Cleaning Validation at Mallinckrodt. With over 20 years total experience in the pharmaceutical and biotech industries, Joy has gained extensive knowledge of Quality Assurance, Process and Cleaning Validation, and Equipment Qualification. She has written and executed Equipment Qualification and Validation Protocols for numerous Companies such as Mallinckrodt, Wyeth Lederle, Merck, BioMerieux, Catalent, and Phillips Medisize. Her knowledge, experience, and strong work ethic have made her a highly sought-after engineer in both the pharmaceutical and biotech industries. Joy specializes in Equipment Qualification, Sterilization, Cleaning Validation, and GMP Compliance Auditing. In 2013 Joy started her own company, Maynard Consulting Company, which provides top engineers, auditors, and validation specialist to pharmaceutical, biotech and medical device clients across the United States, Canada, and the world.
Lecture 1 :
- Requirements and approaches for Analytical Instrument Qualification
- Going through the qualification phases
Lecture 2 :
- Testing and deviation handling
- Retrospective qualification and Requalification
Lecture 3 :
- Equipment Maintenance and Change control
- Type and extend of qualification for USP Instrument Categories
Lecture 4 :
- Requirements and approaches for Laboratory Computer Systems
- Examples for risk assessment of computer systems
Lecture 5 :
- Validation of Laboratory Computer systems
- Preparing inspection ready validation documentation
Lecture 6 :
- Validation and Use of Excel in the QC Laboratory
- How to ensure spreadsheet and data integrity
Lecture 7 :
- Periodic review and revalidation of chromatographic data system
- Handling raw data and other laboratory records
- Ensuring Integrity and Security of Laboratory (Raw) data
Lecture 8 :
- Auditing Laboratory Computer Systems and records for FDA Compliance
- Learn how to avoid or respond to FDA 483s and warning letters